Stainless steel wire mesh problems
Stainless steel wire mesh problems The stainless steel wire mesh breaks during use and is analyzed by chemical composition analysis, inspection, scanning and spectrometer analysis. The results show that the stress corrosion point is the main cause of the fracture of the stainless steel mesh. Corrosive media is the processing of chloride ions or various aqueous solutions in the humid atmosphere...